NEC Code Change

Time limit: 0

Quiz Summary

0 of 110 Questions completed

Questions:

Information

You have already completed the quiz before. Hence you can not start it again.

Quiz is loading…

You must sign in or sign up to start the quiz.

You must first complete the following:

Results

Quiz complete. Results are being recorded.

Results

0 of 110 Questions answered correctly

Your time:

Time has elapsed

You have reached 0 of 0 point(s), (0)

Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)

Categories

  1. Not categorized 0%
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19
  20. 20
  21. 21
  22. 22
  23. 23
  24. 24
  25. 25
  26. 26
  27. 27
  28. 28
  29. 29
  30. 30
  31. 31
  32. 32
  33. 33
  34. 34
  35. 35
  36. 36
  37. 37
  38. 38
  39. 39
  40. 40
  41. 41
  42. 42
  43. 43
  44. 44
  45. 45
  46. 46
  47. 47
  48. 48
  49. 49
  50. 50
  51. 51
  52. 52
  53. 53
  54. 54
  55. 55
  56. 56
  57. 57
  58. 58
  59. 59
  60. 60
  61. 61
  62. 62
  63. 63
  64. 64
  65. 65
  66. 66
  67. 67
  68. 68
  69. 69
  70. 70
  71. 71
  72. 72
  73. 73
  74. 74
  75. 75
  76. 76
  77. 77
  78. 78
  79. 79
  80. 80
  81. 81
  82. 82
  83. 83
  84. 84
  85. 85
  86. 86
  87. 87
  88. 88
  89. 89
  90. 90
  91. 91
  92. 92
  93. 93
  94. 94
  95. 95
  96. 96
  97. 97
  98. 98
  99. 99
  100. 100
  101. 101
  102. 102
  103. 103
  104. 104
  105. 105
  106. 106
  107. 107
  108. 108
  109. 109
  110. 110
  1. Current
  2. Review
  3. Answered
  4. Correct
  5. Incorrect
  1. Question 1 of 110
    1. Question

    Where the conductor material is not specified, the sizes given in this Code shall apply to _____________ conductors.

  2. Question 2 of 110
    2. Question

    Termination provisions of equipment for circuits rated 100 amps or less shall be used only for conductors rated ____ degrees C

  3. Question 3 of 110
    3. Question

    Termination provisions of equipment for circuits rated over 100 amps shall be used only for conductors rated ____ degrees C

  4. Question 4 of 110
    4. Question

    Disconnects shall be legibly marked indicating its _________.

  5. Question 5 of 110
    5. Question

    What is the minimum working space for equipment 480V with live parts on both side of the working space

  6. Question 6 of 110
    6. Question

    The width of the working space in front of the equipment shall be the width of the equipment or ______

  7. Question 7 of 110
    7. Question

    The working space for 240V equipment with a concrete on the other side of the exposed live parts is _____

  8. Question 8 of 110
    8. Question

    What is the minimum height of dedicated space above electrical equipment 480V rated.

  9. Question 9 of 110
    9. Question

    Equipment rated over _____Amps or more, located in a room. The doors shall open in the direction of egress.

  10. Question 10 of 110
    10. Question

    Conductors with _____ marked on the insulation are NOT approved for use in a wet location.

  11. Question 11 of 110
    11. Question

    Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence?

  12. Question 12 of 110
    12. Question

    Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-family dwelling, the full-load current rating, in amperes, of the secondary is _____.

  13. Question 13 of 110
    13. Question

    Which one of the following listed circuit breakers is NOT a standard ampere rating?

  14. Question 14 of 110
    14. Question

    The MINIMUM length of free conductor to be left at each junction box for the purpose of splicing conductors, or making connections to luminaires or devices shall be _____ .

  15. Question 15 of 110
    15. Question

    Switchgears, Distribution Boards, Panelboards, Switchboards, Branch Circuit Panels shall have labels indicating the color code for un-grounded and grounded conductors.

  16. Question 16 of 110
    16. Question

    Equipment such as raceways, cables, wireways, transformers, or support structures are not permitted to extend more than ______” into the working space.

  17. Question 17 of 110
    17. Question

    Why is electrical continuity required for metallic conduit?

  18. Question 18 of 110
    18. Question

    In dwelling units, receptacle outlets installed for countertop surfaces, must be located above, but NOT more than _____ above the countertop or work surface.

  19. Question 19 of 110
    19. Question

    When conductors are installed in a conduit or tubing nipple of _____ or less in length, the ampacity adjustment factors for more than three (3) current-carrying conductors in the raceway, are not required to be applied.

  20. Question 20 of 110
    20. Question

    Receptacles are required on wall spaces that exceed 2′, can a floor receptacle count as a wall space if located within _____”

  21. Question 21 of 110
    21. Question

    Which of the following shall not be located over the steps of a stairway?

  22. Question 22 of 110
    22. Question

    The switch or wall mounted control device must not rely exclusively on a battery to energize the lighting outlet unless a means is provided for automatically energizing the lighting outlets upon battery failure.

  23. Question 23 of 110
    23. Question

    Metal water pipes installed in or attached to a building or structure shall be bonded to _____.

  24. Question 24 of 110
    24. Question

    When armored cable, Type AC, is installed in an accessible attic and is run parallel to the sides of rafters, studs, or floor joists, _____.

  25. Question 25 of 110
    25. Question

    Generally, in a movie theater the manual switch for controlling the emergency lighting systems is permitted to be located _____.

  26. Question 26 of 110
    26. Question

    Single-conductor cable such as _____ and single-conductor cable listed and identified as solar photovoltaic (PV) wire are permitted for use in PV source circuits within the PV array.

  27. Question 27 of 110
    27. Question

    For dwelling units, GFCI protection is required for all single-phase, 125-volt, 15- and 20-ampere receptacles installed within six (6) feet of the top inside edge of the bowl of sinks located in _____.

  28. Question 28 of 110
    28. Question

    For a building or structure where the meter enclosure is adjacent to the service disconnecting means, it is permitted to ground the meter enclosure to the _____ conductor on the load side of the service disconnect if ground-fault protection is not provided.

  29. Question 29 of 110
    29. Question

    Where a 125-volt, 15-ampere receptacle is connected to a 120-volt branch circuit supplying two (2) or more receptacles or outlets, the maximum permitted cord-and-plug-connected load to the receptacle is _____.

  30. Question 30 of 110
    30. Question

    According to the NEC, fixed outdoor deicing and snow melting equipment is to be considered as a _____ load.

  31. Question 31 of 110
    31. Question

    In industrial establishments only, when a 200-ampere rated busway is tapped from a 600-ampere rated busway, what is the maximum permitted length of the 200-ampere busway where overcurrent protection is not provided for the 200-ampere busway?

  32. Question 32 of 110
    32. Question

    When installing nonmetallic sheathed cable enclosed in an underground buried PVC conduit, the cable _____.

  33. Question 33 of 110
    33. Question

    In regard to a commercial building, where a service-entrance conduit having a length of six (6) feet contains four (4) size 2 AWG THWN insulated copper current-carrying conductors, each of the conductors have an allowable ampacity of _____.

  34. Question 34 of 110
    34. Question

    The work space width shall be the width of the equipment or 30″ whichever is greater.

  35. Question 35 of 110
    35. Question

    Equipment used outdoors and exposed to rain, snow and sleet and where the mechanism shall be operable when ice covered must be type

  36. Question 36 of 110
    36. Question

    What is the minimum size of a rectangular manhole?

  37. Question 37 of 110
    37. Question

    A grounding conductor is what color?

  38. Question 38 of 110
    38. Question

    What is the minimum weight of a manhole cover

  39. Question 39 of 110
    39. Question

    A grounded conductor is what color?

  40. Question 40 of 110
    40. Question

    An insulated conductor that is intended for use as a grounded conductor where contained in a flexible cord shall be identified by what color?

  41. Question 41 of 110
    41. Question

    480 Volt lighting in a parking lot is required to be at what height?

  42. Question 42 of 110
    42. Question

    277 Volt lighting in a tunnel is required to no be less than.

  43. Question 43 of 110
    43. Question

    GFCI protection in a dwelling unit is required in

  44. Question 44 of 110
    44. Question

    Branch circuit ratings are identified as circuits under what amperage?

  45. Question 45 of 110
    45. Question

    Branch circuits are not allowed to exceed what percentage of voltage drop?

  46. Question 46 of 110
    46. Question

    Feeder circuits are not allowed to exceed what percentage of voltage drop?

  47. Question 47 of 110
    47. Question

    In no case shall both branch and feeder circuits exceed what percentage of voltage drop?

  48. Question 48 of 110
    48. Question

    Continuous loads are loads that are expected to run for how many hours?

  49. Question 49 of 110
    49. Question

    Covered conductors are recognized by the Code

  50. Question 50 of 110
    50. Question

    Where conductors supply continuous loads the conductor shall have an ampacity rating not less than what percentage?

  51. Question 51 of 110
    51. Question

    What is the maximum ampacity of a 20 amp breaker?

  52. Question 52 of 110
    52. Question

    What is the minimum size conductor for 20A branch circuit?

  53. Question 53 of 110
    53. Question

    What is the minimum size conductor for 15A branch circuit?

  54. Question 54 of 110
    54. Question

    What is the minimum length/space of a wall

  55. Question 55 of 110
    55. Question

    Cord and plug type equipment not fastened in place shall not exceed what percentage of the branch circuit ampere rating?

  56. Question 56 of 110
    56. Question

    Cord and plug type equipment fastened in place shall not exceed what percentage of the branch circuit ampere rating?

  57. Question 57 of 110
    57. Question

    Receptacles shall be installed so that at no point the wall space is greater than _____’ from a receptacle outlet.

  58. Question 58 of 110
    58. Question

    A least 1 receptacle outlet shall be accessible from the deck, balcony, or porch. The outlet shall not be located more than _______ above the deck, balcony, or porch.

  59. Question 59 of 110
    59. Question

    In each attached garage and in each detached garage with electric power, at least one receptacle outlet shall be installed in each vehicle bay and not more than ______.

  60. Question 60 of 110
    60. Question

    Receptacle outlets shall be calculated at not less than ______ va for each single yoke.

  61. Question 61 of 110
    61. Question

    In general how many receptacles can be installed on a single 120V 20 amp circuit?

  62. Question 62 of 110
    62. Question

    What is the minimum va for a clothes dryer?

  63. Question 63 of 110
    63. Question

    If the AC load is 15,000va and the heating load is 20,000va which one is used when calculating total load?

  64. Question 64 of 110
    64. Question

    For 1000 volts, nominal or less what is the minimum size copper conductor for spans up to 50′?

  65. Question 65 of 110
    65. Question

    For over 1000 volts, nominal what is the minimum size copper conductor in a cable?

  66. Question 66 of 110
    66. Question

    Over what length would 12 awg festoon lighting need to be supported by a messenger wire?

  67. Question 67 of 110
    67. Question

    What is the minimum size AWG for festoon lighting?

  68. Question 68 of 110
    68. Question

    What is the minimum clearance for conductors less than 1000 volts over a side walk?

  69. Question 69 of 110
    69. Question

    What is the minimum distance that conductors, weatherheads, and service entrances, shall be kept from windows, doors, porches, balconies, and fire escapes?

  70. Question 70 of 110
    70. Question

    Trees are allowed to be used as supports for overhead conductors.

  71. Question 71 of 110
    71. Question

    What is the maximum number of disconnecting means per supply?

  72. Question 72 of 110
    72. Question

    Underground service entrance conductors are not permitted in.

  73. Question 73 of 110
    73. Question

    The minimum underground service entrance conductor in copper is.

  74. Question 74 of 110
    74. Question

    What is the minimum size for single conductors in cable tray as a service entrance.

  75. Question 75 of 110
    75. Question

    What is the maximum continuous load for 18 AWG copper.

  76. Question 76 of 110
    76. Question

    What is the maximum continuous load for 16 AWG copper.

  77. Question 77 of 110
    77. Question

    What is the maximum continuous load for 12 AWG copper.

  78. Question 78 of 110
    78. Question

    Fixture wires are allowed to be tapped to a branch circuit. What is the minimum size for a 20 amp circuit.

  79. Question 79 of 110
    79. Question

    What size conductor is required for field assembled extension cords, with flexible cords and separately listed and installed components supplied by a 20 amp branch circuit.

  80. Question 80 of 110
    80. Question

    Which of the follow is not a standard ampere rating for a circuit breaker.

  81. Question 81 of 110
    81. Question

    Which of the follow is not a standard ampere rating for a circuit breaker.

  82. Question 82 of 110
    82. Question

    Which of the follow is not a standard ampere rating for a fuse.

  83. Question 83 of 110
    83. Question

    Circuit breakers shall open all grounded conductors.

  84. Question 84 of 110
    84. Question

    For tap conductors that don’t exceed 10′ in length, and the conductors leave the enclosure in which the tap is made, the ampacity of the tap conductors shall not be less than ________ of the rating of the overcurrent protective device.

  85. Question 85 of 110
    85. Question

    Tap conductors supplying a transformer not over 25′ in length, the tap conductor shall have an ampacity rating of at least ________ the rating of the overcurrent protective device.

  86. Question 86 of 110
    86. Question

    Plug Edison-Base fuses shall be classified at not over 125 volts and ______ amps and below.

  87. Question 87 of 110
    87. Question

    Circuit breakers shall clearly indicate whether they are on or off. In the up position a breaker shall be off.

  88. Question 88 of 110
    88. Question

    Circuit breakers used as switches in 120 volt and 277 volt fluorescent lighting shall be marked.

  89. Question 89 of 110
    89. Question

    Circuit breakers used as switches in 120 volt and 277 volt high-intensity lighting shall be marked.

  90. Question 90 of 110
    90. Question

    Breakers that are marked SWD are approved to control light fixtures of what type.

  91. Question 91 of 110
    91. Question

    If a panel is straight rated 480v what type of rating(s) are the breakers required to have?

  92. Question 92 of 110
    92. Question

    If a panel is slash rated 480/277v what type of rating(s) are the breakers required to have?

  93. Question 93 of 110
    93. Question

    Receptacles are not allowed to be installed horizontally.

  94. Question 94 of 110
    94. Question

    Which of the following are not permitted for use as a grounding electrode?

  95. Question 95 of 110
    95. Question

    Receptacles shall not be installed in a _________ position in countertop surfaces or work surfaces.

  96. Question 96 of 110
    96. Question

    Aluminum, copper-clad aluminum, or copper conductors, for each phase, polarity, neutral, or grounded circuit shall be permitted to be connected in parallel only in sizes __________ and larger.

  97. Question 97 of 110
    97. Question

    Where the supplemental electrode is a rod, pipe, or plate electrode, that portion of the bonding jumper that is the sole connection to the supplemental grounding electrode shall not be required to be larger than _________ copper wire.

  98. Question 98 of 110
    98. Question

    An electrode encased by at least 2″ of concrete shall be permitted to be 20′ of base copper conductor not smaller than _________ AWG

  99. Question 99 of 110
    99. Question

    Where the service-entrance phase conductors are installed in parallel, in two or more raceways, the size of the grounded conductor in each raceway shall not be smaller than _______ AWG

  100. Question 100 of 110
    100. Question

    Overhead service-drop conductors shall not be smaller than ________ copper.

  101. Question 101 of 110
    101. Question

    Fixtures wires shall not be smaller than ________ AWG

  102. Question 102 of 110
    102. Question

    Overhead conductors for festoon lighting shall not be smaller than ________ unless the conductors are supported by messenger wires.

  103. Question 103 of 110
    103. Question

    Show windows must be calculated either at 200 volt-amps per _________ of show window, or the unit load per outlet as required in other provisions of article 220.14

  104. Question 104 of 110
    104. Question

    What is the minimum computed branch circuit load, in volt-amps, allowed by the NEC for a branch circuit serviing an exterior electric sign, when calculating a building or structure’s total load?

  105. Question 105 of 110
    105. Question

    If a warehouse uses mercury vapor lighting in the storage area, and the storage area is 40,500 square feet of space, what is the minimum lighting load?

  106. Question 106 of 110
    106. Question

    An insulated grounded conductor larger then _______ shall be permitted to be marked with white tape at the time of installation.

  107. Question 107 of 110
    107. Question

    Live parts of electrical equipment operating at ________ nominal shall be guarded against accidental contact.

  108. Question 108 of 110
    108. Question

    Connection by means of wire-binding screws or studs and nuts that have upturned lugs or the equivalent shall be permitted for _________ AWG or smaller conductors.

  109. Question 109 of 110
    109. Question

    What is the lighting demand factor in hospitals.

  110. Question 110 of 110
    110. Question

    If each unit in a 12 unit condo had an 8kW electric range, applying the optional method of calculation for multifamily dwellings, what would the calculated demand load be on the ungrounded service entrance conductors for the electric ranges?